26
The individual selection options are explained in greater detail below:
The following settings are available for electrolyte circulation:
-
Off:
-
Electrolyte circulation switched off
-
Continuous:
-
Electrolyte circulation permanently on
-
Program 1 to 5:
-
Default electrolyte circulation programs
-
More information on the programs can be found under "Electrolyte circulation" in
the "Options" section
-
Automatic:
-
Automatic adjustment of the electrolyte circulation as dictated by the situation
-
"User" - "On"/"Off":
-
Individual setting of the electrolyte circulation
-
The settings for "On" and "Off" determine the pulse/pause ratio of the air flow in-
tervals
The following settings are available for temperature-controlled charging:
-
automatic/OFF/required:
-
automatic ... Temperature-dependent adjustment of the charging characteristic
-
OFF ... The measured battery temperature is not taken into account
-
required ...
Charging only starts when a temperature sensor is connected
A list appears with the following selection options:
Electrolyte circulation ("Air Pump"):
Temperature-controlled charging: