Fronius Selectiva 8 kW User Manual
Page 33

31
EN
In conjunction with the "Temperature-controlled charging" option, a temperature value can
be set here. The blue "battery cooled down" indicator will light up to signal a sufficiently-
cooled battery once the temperature drops below this value.
The following settings are available when external start/stop is selected:
-
Start:
normal ON:
-
Charging starts when an external switch is closed and a battery is detected
-
Or when the charging plug is connected by closing the auxiliary contacts and a
battery is detected
normal OFF:
-
Charging starts when a battery is connected
-
Stop:
normal ON:
-
Charging is interrupted when an external switch is opened
-
Or when the charging plug is disconnected by opening the auxiliary contacts
normal OFF:
-
Opening of an external switch or the auxiliary contacts is ignored
-
Button:
The function of the "Stop/Start" key can be simulated using an external button
Refill Indicator:
The refill indicator is a message that appears as soon as the battery needs topping up with
distilled water. The time at which refilling is deemed necessary can be defined as follows:
-
days: number of days that have passed since the message was last output or the op-
tion was set
-
charge count: number of charges that have been performed since the message was
last output or the option was set
External start/stop:
Relays: