beautypg.com

Foxconn FlamingBlade User Manual

Page 52

background image

45

3

Memory Settings

► IMC Configuration

This item is used to enable or disable memory parameter settings.

► Channel Configuration

Options are: Independent, Mirror, Lock, Spare.

► Channel Interleaving

This item is used to set Max. DRAM channel interleave. Options are: from 1 way to 6 way.

► Rank Interleaving

Interleaving allows banks of SDRAM to alternate their refresh and access cycles. One
bank will undergo its refresh cycle while another is being accessed. This improves memory
performance by masking the refresh cycles of each memory bank.
However, bank interleaving only works if the addresses requested consecutively are not in the
same bank. Option are: 1 way, 2 way and 4 way.

► Virtual XMP

Intel XMP is a performance-packed expansion of the standard DDR3 memory specification,
enabling a robust, overclocking solution designed to take advantage of the mega-gaming
features built into Intel® technology-based PCs. If you like to overclock and squeeze every
possible ounce of performance from your PC, then memory based on Intel XMP is the solution
you need to destroy your enemies and save the universe without breaking a sweat.
This item is used to enable or disable Intel XMP.

► tCL (CAS Latency)

This item controls the CAS latency, which determines the timing delay (in clock cycles) before
SDRAM starts a read command after receiving it.

► tRCD (RAS to CAS Delay)

This item allows you to select a delay time (in clock cycles) between the CAS and RAS strobe

signals.

► tRP (RAS Precharge)

This item allows you to select the DRAM RAS precharge time (in clock cycles).

► tRAS (Precharge Delay)

This item allows you to set the precharge delay time (in clock cycles).

Phoenix - AwardBIOS CMOS Setup Utility

Memory Settings

******** Memory Controller Settings ********

Item Help

IMC Configuration

Enabled

Channel Configuration

Independent

Menu Level ►

Channel Interleaving

6 way

Rank Interleaving

4 way

************** Memory Timings **************

Virtual XMP

Disabled

x DRAM Timing Control

By SPD

x tCL (CAS Latency)

Auto

x tRCD (RAS to CAS Delay)

Auto

x tRP (RAS Precharge)

Auto

x tRAS (Precharge Delay)

Auto

x CR (Command Rate)

Auto

x tRFC (Refresh Cycle Time)

Auto

x tWR (Write Recovery Time)

Auto

x tWTR (Write to Read Delay)

Auto

x tRRD (RAS to RAS Delay)

Auto

x tRTP (Read to Precharge)

Auto

↑↓→←:Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit F1:General Help

F5:Previous Values F7:Optimized Defaults

Enabled

This manual is related to the following products: