beautypg.com

Raid configuration 93 – Foxconn B75M User Manual

Page 100

background image

RAID CONFIGURATION

93

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

1. Create RAID Volume

4. Recover Volume Options

2. Delete RAID Volume

5. Acceleration Options

3. Reset Disks to Non-RAID

6. Exit

RAID Volume :

ID

Name

Level Stripe

Size Status Bootable

0

TryRAID5

RAID5(Parity) 64KB 149.1GB

Normal

Yes

Physical Disks:

Port Drive Model

Serial #

Size Type/Status(Vol ID)

0

Hitachi HDS72161

PVF904Z21G2JZM

149.0GB

Member Disk(0)

1

ST380811AS

5PS1TAGW

74.5GB

Member Disk(0)

2

SAMSUNG HD161HJ S0V3J9APA30524

149.0GB

Non-RAID Disk

3

ST380815AS

5RW1CA37

74.5GB

Non-RAID Disk

Intel(R) Rapid Storage Technology - Uption ROM - 11.0.8.1204

Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.

[

DISK/VOLUME INFORMATION

]

[

MAIN MENU

]

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

"Degraded" volume and disk available for rebuilding detected. Selecting

a disk initiates a rebuild. rebuild completes in the operating system.

Select the port of the destination disk for rebuilding (ESC to exit):

Port Drive Model

Serial #

Size

2 SAMSUNG HD161HJ

S0V3J9APA30524

140.9GB

3 ST380815AS

5RW1CA37

74.5GB

[

DEGRADED VOLUME DETECTED

]

3 ST380815AS

5RW1CA37

74.5GB

[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit

5. It goes back to Main menu with a "Rebuild" status of RAID5 volume. Eventually, a replace-
ment hard disk has to join in and it always keeps three hard disks in the RAID5 system.
6. Operating System will perform the rebuilding later.

Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5

Copyright(C) 2003-04 Intel Corporation All Rights Reserved.

1. Create RAID Volume

4. Recovery Volume Option

2. Delete RAID Volume

5. Acceleration Options

6. Exit

RAID Volume :

ID

Name

Level Stripe

Size Status Bootable

0

TryRAID5

RAID5(Parity) 64KB 149.1GB

Rebuild

Yes

Physical Disks:

Port Drive Model

Serial #

Size Type/Status(Vol ID)

0

Hitachi HDS72161

PVF904Z21G2JZM

149.0GB

Member Disk(0)

1

ST380811AS

5PS1TAGW

74.5GB

Member Disk(0)

2

SAMSUNG HD161HJ S0V3J9APA30524

149.0GB

Non-RAID Disk

3

ST380815AS

5RW1CA37

74.5GB

Member Disk(0)

Volume with “Rebulid” status will be rebuilt within the operating system.

Intel(R) Rapid Storage Technology - Uption ROM - 11.0.8.1204

Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.

[

DISK/VOLUME INFORMATION

]

[

MAIN MENU

]

3. Reset Disks to Non-RAID

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu