KEYBOARD FAULT

When powered up,

one or more keys on

the keyboard are

depressed.

Check if one key is not

stuck.

CHECK THE

REAR GUIDE

OF THE

ENVELOPE TRAY

Envelope size does not

match the position of

the rear guide.

Double envelope

detected.

Adjust the rear guide of the

envelope tray (tray E)

according to the size of the

envelopes

Open the machine and

check that the envelope

path is clear.

CHECK THE

ENVELOPE PATH

Envelope jammed in

the machine.

Open the machine and check

the envelope path

.

CHECK THE

WATER TANK

This message is only

a reminder.

Open the machine, check the

water level and fill up the

reservoir if necessary. (See

Chapter "Filling the

moistening tray")

Screen message

Probable

Cause(s)

Remedy