2 multi turn encoder. qxm-1 thru 5, all rpms, 1 multi turn encoder removal – Flowserve QX Limitorque User Manual
Page 50
Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11
50
5.2 Multi Turn Encoder. QXM-1 thru 5, all RPMs
Table - 5.3 Multi-Turn Encoder Assembly
ITEM NUMBER
DESCRIPTION
(6.5 TURN)
DESCRIPTION
(20 TURN)
QTY.
(QX-1 &2)
QTY.
(QX-3 THRU 5)
17-1
DOWEL PIN
DOWEL PIN
1
1
17-2
6.5 TURN SPUR GEAR ASSY
SPUR GEAR ASSY
1
1
17-3
SOC HEAD CAP SCREW
SOC HEAD CAP SCREW
2
2
17-4
SPACER
SPACER
2
NA
17-5
SOCKET HEAD CAP SCREWS
SOCKET HEAD CAP SCREWS
2
2
17-6
SOCKET HEAD CAP SCREWS
SOCKET HEAD CAP SCREWS
3
3
Figure 5.4 - Multi-turn Encoder Assembly
5.2.1 Multi Turn Encoder Removal
Step 1
NOTE: The terminal block and power controls must be removed before removing the encoder. See section 6.4 for
terminal block and controls removal.
Disconnect the encoder ribbon cable connector from the Motor controller board, See section 6 for connector
placement. Using M3 Hex key remove the three screws (#17-6) that mount the encoder. Gently pull the encoder up and
out of the housing thru the terminal block bore.
Step 2
Using M3 Hex key (QX-1 & 2) or M2.5 Hex key (QX-3 thru 5) remove the two screws (#17-5) that mount the encoder
spur gear subassembly to the two housing pads.