3 seal drive cap screw retainer installation – Flowserve PSS III Durametallic User Manual
Page 5
5
Note: For all standard size seals (.125 inch increments), the rotating
face gasket, seat gasket and sleeve gasket are cut to the proper
length at the factory and require no further trimming. These gaskets
will appear to be too long for the groove. The extra length of the
gasket will be compressed into the groove between the glued
points at each joint during seal assembly. See Figure 7.
3 Seal Drive Cap Screw Retainer Installation
0.65 - 0.90 mm
(0.025 - 0.035 inch)
Split Joint Gasket Groove
Rotating Face Gasket,
Seat Gasket, or Sleeve
Gasket
Seal Drive
or Gland
0.65 - 0.90 mm
(0.025 - 0.035 inch)
Figure 3
Figure 4
3.1 Using a sharp blade, cut the supplied 568112GU O-ring in half.
3.2 Apply adhesive into the 3.05 mm (0.120 inch) diameter partial hole
located to the side of the cap screw hole. Push the end of one
O-ring half into the hole and hold it in place for 10 seconds. When
the adhesive has set up, use a
sharp blade and trim the O-ring
flush with the seal drive joint
surface. See Figure 4.
3.4 Repeat this procedure for the
other seal drive half.
Cut O-ring