Warning mechanical seal fitted, Warning – Flowserve FRBH User Manual
Page 8

FRBH, FRBHX AND FRBHS USER INSTRUCTIONS ENGLISH 71569178 10-04
Page 8 of 54
®
occur if there is heat input to the liquid. This can occur 
if the pump is stationary or running. 
 
Bursting of liquid containing parts due to freezing must 
be avoided by draining or protecting the pump and 
ancillary systems. 
 
Where there is the potential hazard of a loss of a seal 
barrier fluid or external flush, the fluid must be 
monitored. 
 
If leakage of liquid to atmosphere can result in a 
hazard, the installation of a liquid detection device is 
recommended. 
 
1.6.4.7 Maintenance to avoid the hazard 
CORRECT MAINTENANCE IS REQUIRED TO
AVOID POTENTIAL HAZARDS WHICH GIVE A RISK 
OF EXPLOSION 
The responsibility for compliance with maintenance 
instructions is with the plant operator. 
To avoid potential explosion hazards during 
maintenance, the tools, cleaning and painting materials 
used must not give rise to sparking or adversely affect 
the ambient conditions. Where there is a risk from 
such tools or materials, maintenance must be 
conducted in a safe area. 
 
It is recommended that a maintenance plan and 
schedule is adopted. (See section 6, Maintenance.) 
1.7 Nameplate and warning labels 
 
1.7.1 Nameplate 
For details of nameplate, see the Declaration of Conformity. 
 
1.7.2 Warning labels 
 
 
 
 
 
 
 
MECHANICAL SEAL WARNING
ROTATION WARNING
P/N 2113931-001
P/N 2113932-001
 
 
 
 
 
 
 
 
 
 
 
 
GROUT WARNING
LIFTING WARNING
P/N 2113934-001
P/N 9901701-001
WARNING
MECHANICAL SEAL FITTED
DO NOT ADJUST PUMP CLEARANCE
WITHOUT REFERENCE TO
MANUFACTURER’S INSTRUCTION MANUAL
WARNING
BEFORE STARTING THE PUMP ON SERVICE,
CHECK TO ENSURE CORRECT ROTATION OF
MOTOR. FAILURE TO DO THIS COULD RESULT
IN SERIOUS DAMAGE TO THE EQUIPMENT.
WARNING
BEFORE GROUTING, REALIGN THIS UNIT.
RECHECK ALIGNMENT BEFORE STARTING,
FAILURE TO DO THIS COULD RESULT IN 
SERIOUS DAMAGE TO THE EQUIPMENT. 
REFER TO INSTALLATION MANUAL AND, OR
COUPLING INSTRUCTIONS FOR METHOD OF
CHECKING ALIGNMENT.
WARNING
THESE EYEBOLTS
ARE TO BE USED FOR LIFTING BEARING
CARTRIDGE AND SHAFT ONLY.
DO NOT USE FOR LIFTING ENTIRE UNIT