Flowserve FRBH User Manual
Page 10

FRBH, FRBHX AND FRBHS USER INSTRUCTIONS ENGLISH 71569178 10-04
Page 10 of 54
®
1.8 Specific machine performance 
For performance parameters see section 1.5, Dut y 
conditions. When the contract requirement specifies 
these to be incorporated into User Instructions these 
are included here. Where performance data has been 
supplied separately to the purchaser these should be 
obtained and retained with these User Instructions if 
required. 
 
1.9 Noise level 
When pump noise level exceeds 85 dBA attention must 
be given to prevailing Health and Safety Legislation, to 
limit the exposure of plant operating personnel to the 
noise. The usual approach is to control exposure time 
to the noise or to enclose the machine to reduce 
emitted sound. You may have already specified a 
limiting noise level when the equipment was ordered, 
however if no noise requirements were defined then 
machines above a certain power level will exceed 85 
dBA. In such situations consideration must be given to 
the fitting of an acoustic enclosure to meet local 
regulations. 
Pump noise level is dependent on a number of factors - 
the type of motor fitted, the operating capacity, 
pipework design and acoustic characteristics of the 
building. The levels specified in the table below are 
estimated and not guaranteed. 
 
The dBA values are based on the noisiest ungeared 
electric motors that are likely to be encountered. They 
are Sound Pressure levels at 1 m (3.3 ft) from the 
directly driven pump, for "free field over a reflecting 
plane". For estimating L
wA
sound power level (re 1 pW)
add 14dBA to the sound pressure value. 
 
If a pump unit only has been purchased, for fitting with 
your own driver, then the "pump only" noise levels from 
the table should be combined with the level for the 
driver obtained from the supplier. If the motor is driven 
by an inverter, it may show an increase in noise level at 
some speeds. Consult a Noise Specialist for the 
combined calculation. 
 
&
For units driven by equipment other than
electric motors or units contained within enclosures, 
see the accompanying information sheets and 
manuals. 
 
 
 
FRBH pump size
Sound Pressure dBA
(at 1 m (3 ft) reference 20 µPa)
Pump speed
rpm
Sound Power
Level dBA
2 FRBH-121
75
1780
89
3 FRBH-121
75
1780
89
3 FRBH-101
75
1780
89
3 FRBH-141
77
1780
91
4 FRBH-111
77
1780
91
4 FRBH-141
78
1780
91
6 FRBH-111
80
1780
94
6 FRBH-142
81
1780
95
8 FRBH-182
83
1780
98
8 FRBH-152
85
1780
100
10 FRBH-182
85
1180
100
12 FRBH-233
85
1180
100
18 FRBH-274
87
885
102
 
 
 
 
 
 
 