5.2 Pump lubricants
5.2.1 Recommended oil lubricants
Oil
Splash lubrication
Force feed lubrication
Viscosity
mm ²/s 40 ºC
32
68
46
Temp. maximum
ºC (ºF)
65 (149)
80 (176)
-
Centifugal pump
lubrication
Designation
according to
DIN51502 ISO VG
HL/HLP 32
HL/HLP 68
HL/HLP 46
BP
BP Energol HL32
BP Energol HLP32
BP Energol HL68
BP Energol HLP68
BP Energol HL46
BP Energol HLP46
DEA
Anstron HL32
Anstron HLP32
Anstron HL68
Anstron HLP68
Anstron HL46
Anstron HLP46
Elf
OLNA 32
HYDRELEF 32
TURBELF 32
ELFOLNA DS32
TURBELF SA68
ELFOLNA DS68
TURBELF SA46
ELFOLNA DS46
Esso
TERESSO 32
NUTO H32
TERESSO 68
NUTO H68
TERESSO 46
NUTO H46
Mobil
Mobil DTE oil light
Mobil DTE13
MobilDTE24
Mobil DTE oil heavy medium
Mobil DTE26
Mobil DTE oil medium
Mobil DTE15M
Mobil DTE25
Q8
Q8 Verdi 32
Q8 Haydn 32
Q8 Verdi 68
Q8 Haydn 68
Q8 Verdi 46
Q8 Haydn 46
Shell
Shell Te llus 32
Shell Tellus 37
Shell Tellus 01 C 68
Shell Tellus 01 68
Shell Tellus 01 C 46
Shell Tellus 01 46
Texaco
Rando Oil HD 32
Rando Oil HD-AZ-32
Rando Oil 68
Rando Oil HD C-68
Rando Oil 46
Rando Oil HD B-46
Oil companies and lubricants
Wintershall
(BASF Group)
Wiolan HN32
Wiolan HS32
Wiolan HN68
Wiolan HS68
Wiolan HN46
Wiolan HS46
5.2.2 Recommended grease lubricants
Grease nipples
Grease
NLGI 2 *
NLGI 3 **
Temp. range ºC
(ºF)
-20 to +100
(-4 to +212)
-20 to +100
(-4 to +212)
Designation
according to DIN
K2K-20
K2K 30
BP
Energrease LS2
Energrease LS3
DEA
Glissando 20
Glissando 30
Elf
Elfmulti 2
Elfmulti 3
Esso
Beacon 2
Beacon 3
Mobil
Mobilux 2
Mobilux 3
Q8
Rembrandt 2
Rembrandt 3
Shell
Alvania Fett G2
Alvania Fett R2
Alvania R3
Texaco
Multilak 20
Multilak EP2
Multilak 30
Multilak EP3
Wintershall
(BASF Group)
Wiolub LFK 2
-
SKF
LGMT 2
LGMT 3
Silkolene
G55/T
G56/T
* NLGI 2 is an alternative grease and is not to be mixed with other
grades
** Factory packed bearings for the temperature range with grease
nipples
5.2.3 Recommended fill quantities
Refer to section 3.4.2, Pump and impeller data.
5.2.4
Lubrication schedule
5.2.4.1 Oil lubricated bearings
Normal oil change intervals are 4 000 operating hours
or at least every 6 months. For pumps on hot service
or in severely damp or corrosive atmosphere, the oil will
require changing more frequently. Lubricant and
bearing temperature analysis can be useful in
optimizing lubricant change intervals.
The lubricating oil should be a high quality mineral oil
having foam inhibitors. Synthetic oils may also be used
if checks show that the rubber oil seals will not be
adversely affected.
The bearing temperature may be allowed to rise to
50 ºC (122 ºF).above ambient, but should not exceed
82 ºC (180 ºF). A continuously rising temperature, or
an abrupt rise, indicate a fault.