7 FAULTS; CAUSES AND REMEDIES
Trouble
Cause
Remedy
Insufficient Capacity
Speed to low
Check power supply to motor for
correct voltage.
Wrong rotation
Reconnect motor leads
Foreign material in impeller,
casing, diffusion vanes, and/or
discharge head nozzle
Dismantle pump and remove any
foreign material
Mechanical defects:
Impeller damaged.
Share impeller key.
Dismantle pump and check
Insufficient supply of water to be
pumped
Determine proper level of water in
sump and proper pump
submergence.
Pump vibrates
Loose mounting or coupling
bolts.
Broken or worn pieces
Tighten bolts
Inspect and replace same
Coupling misalignment
Check alignment and correct
Cavitation
Determine proper level of water in
sump and proper pump
submergence
Foreign material in impeller
causing unbalance.
Dismantle pump and remove
foreign material.
Mechanical defects:
Shaft bent.
Bearing worn.
Dismantle pump and replace part
or parts causing vibration
Pump overloads driver
Speed to high
Check power supply for correct
frequency
Pump bearing Seize or rotating
element binds
Check rotor setting. Dismantle
pump and replace parts causing
rubbing, seizures or binding.
Pump stops abruptly
Pump binding at running fits
Dismantle pump and correct
Stuffing box overheats
Stuffing box packed too tight
Repack stuffing box with new
packing per “Stuffing Box
Packing” instructions.
Insufficient Leakage in packing
Loosen gland nuts and retighten
finger tight or until proper leakage
is obtained
Excessive Gland
Leakage
Packing not seated
Gland not tighten evenly loosen
nuts and tighten evenly. (see
“Stuffing Box Packing”
instructions)
Worn Packing
Replace packing
Pump is noisy
Cavitation
Determine proper level of water in
sump and proper pump
submergence
Loose parts
Tighten or replace defective parts
Noise in driver
Check driver IOM manual
Refer to driver manufacturer´s instruction manual for trouble shooting of driver