Flowserve VF User Manual
Page 24

VF USER INSTRUCTIONS ENGLISH 71561233 - 11/09
Page 24 de 32
Lubrification frequency in hours*
Pump type
730 min
-1
970 min
-1
1450 min
-1
Quantity
(gr)
VF 40-20
≤
3 stages
8000
35
VF 40-20
> 3 stages
8000
100
VF 60-18
≤
3 stages
8000
35
VF 60-18
> 3 stages
8000
100
VF 78-37
8000
100
VF 95-27
8000
100
VF 180-27
8000
8000
100
VF 190-19
8000
100
VF 185-35
1 stage
8000
100
VF 185-35
> 1 stage
7500
180
VF 250-43
1 stage
8000
100
VF 250-43
>1 stage
7500
180
VF 240-51
1 stage
8000
100
VF 240-51
> 1 stage
7500
180
VF 300-37
7500
180
VF 310-25
7500
180
VF 460-31
8000
7500
180
VF 550-29
1 stage
8000
180
VF 550-29
>1 stage
3500
60
* At least once a year
The grease used in factory for first filling is:
SHELL ALVANIA R2
Its equivalents:
MOBIL : Mobilux EP 2,
TOTAL : Multis 2,
ELF : ELF MULTI
Grease nipple
6.2.2 Routine inspection (daily / weekly)
The following checks should be
made and the appropriate action taken to remedy
any deviations:
a) Check the behaviour of the pump while
running: noise level, vibrations, bearings
temperature, flow rate and pressure.
b) Check that there are no abnormal fluid or
lubricant leaks (static and dynamic seals) and
that any sealant systems (if fitted) are full and
operating normally.
c) Check the level and condition of oil lubricant.
On grease lubricated pumps, check running
hours since last recharge of grease or
complete grease change.
6.2.3 Periodic inspection (6 monthly)
a)
Check foundation bolts for
security of attachment and corrosion.
b) Check pump running records for hourly usage
to determine if bearing lubricant requires
changing.
c) The coupling should be checked for correct
alignment and worn driving elements.
If a check shows a bad running of the
motor pump unit, the user must:
a)
Refer to the "fault finding chart"
chapter 7 of this leaflet to apply the
recommended solutions.
b) Ensure that your equipment corresponds to
the arrangements of this leaflet.
c) Contact FLOWSERVE after-sales Department
if the problem persists.