Flowserve IDP CPXV User Manual
Page 17

CPXV and CPXRV USER INSTRUCTIONS ENGLISH 71569193 09-14
Page 17 of 48
flowserve.com
Shaft
Denco oiler
setting
Trico oiler
setting
Size
Dia X (mm)
Y (mm)
Z (mm)
C (mm)
1
2
3
4
24
32
42
48
14.5
16.5
17.0
13.5
21.5
23.5
24.0
20.5
12.5
14.5
15.0
11.5
Trico oiler
The l
evel setting for a Trico oiler model must
be as the Trico setting in the table.
Pumps with grease lubricated antifriction bearings are
normally supplied fitted with grease nipples and with
pre-greased bearings.
Grease lubricated electric motor bearings are generally
pre-greased. Refer to the motor UI for information on
the motor lubrication schedule.
Pumps with grease lubricated thrust bearings and
electric motors are supplied with pre-greased bearings.
In the case of product lubricated
bearings the source of product supply should be
checked against the order; there may be requirements
for an external clean supply, particular supply pressure
or the commencement of lubrication supply before
pump start-up.
Approximate oil volumes are shown in section 0,
Bearing sizes and capacities.
Where the ambient is very low special lubricants are
required. If in doubt consult Flowserve for
recommendations of oil and grease types at these
lower temperatures
. Where oil lubrication is utilized
and the ambient is less than -5 °C (23 °F) ensure the
ambient is no lower than 15 °C (27 °F) over the oil
pour point or use the oil class SAE 5W-50 or API-SJ
and ensure the upper operating range of the oil is
then not exceeded. Where low ambient grease has
been specially fitted this is Shell Aeroshell 22.
X