Installation requirements (cont.) – Fire Magic Aurora Single Sideburner Slide-in 3279 Series User Manual
Page 9

9
L-C2-189
REV 7 - 1407151420
The control panel MUST remain removable for servicing
(see PARTS LIST).
ENSURING PROPER COMBUSTION AIR AND
COOLING AIRFLOW
Proper airfl ow (Fig. 9-1) MUST be maintained for the
sideburner to perform as it was designed. If airfl ow is
blocked, overheating and poor combustion will result. Do
not block the 1" (2.5 cm) front air inlet along the bottom
of the control panel or more than 75% of the cooking
grid surface with pans or griddles.
EXHAUST REMOVAL
If installed or used under a patio roof, the cooking grid
area must be fully covered by an exhaust hood with a vent.
An exhaust fan with a rating of 1,000 CFM (cubic feet per
minute) (472 liters per second) or more may be necessary
to effectively remove smoke and other cooking by-products
from the area under the hood. Fire Magic Vent Hoods
are available to meet this requirement. This unit must
not be used under unprotected overhead combustible
construction. THIS UNIT MUST NOT BE LOCATED IN
A FULLY ENCLOSED AREA OF ANY KIND.
GAS-SUPPLY PLUMBING REQUIREMENTS
For natural gas or a household propane system, rigid
1
/
2
"
(1.3 cm) or
3
/
4
" (1.9 cm) black steel pipe or local code-
approved pipe is required to conduct the gas supply to
the unit. Contact your local gas supplier. Connect this
pipe to a required C.S.A.-approved stainless-steel fl ex
connector. DO NOT use a rubber hose within the unit
enclosure. Apply only joint compounds that are resistant
to all gasses to all male pipe fi ttings except fl are fi ttings.
Make sure to tighten every joint securely.
Note: If
1
/
2
" (1.3 cm) pipe is used with natural gas,
it should be no longer than 20' (6.1 meters).
Important:
An external valve (with a removable
key) in the gas line is necessary
for safety when the unit is not in
use. It also provides for convenient
maintenance.
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column
(w.c.), minimum 5" (12.7 cm), maximum 10
1
/
2
" (26.7
cm). For propane gas - normal 11" w.c., minimum 10"
(25.4 cm), maximum 13" (33 cm).
INSTALLATION REQUIREMENTS (Cont.)
Fig. 9-1 Ventilation Diagram
DO NOT BLOCK
MORE THAN 75% OF
COOKING AREA