INSTALLATION REQUIREMENTS

This single sideburner is designed for outdoor use only. DO NOT
use this unit inside a building, garage, enclosed area, or under
an unprotected overhead combustible construction. See the
EXHAUST REMOVAL section on the following page for details
on installing under a patio roof. DO NOT use this unit in or on a
recreational vehicle or boat.

Important: If installing this unit in a combustible surround, the

correct air gap requirement must be met.

Important: Refer to the information below to ensure all

required clearances are met.

The unit must have a minimum clearance of 18" from
combustible materials/items
AT ALL TIMES.

For the minimum clearances between the unit and any side or rear
walls, your setup must fall within one (or more) of the following:

A. Clearance between sideburner and strictly non-

combustible wall
(i.e. brick wall, see Fig. 8-1)

• The unit must have a minimum of 4" right, left, and rear

clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)

B. Clearance between sideburner and a protected

combustible wall
(i.e. a non-combustible wall in front of a combustible wall to
serve as a barrier. This can be accomplished by brick, or
a metal stud fi nished with non-combustible substrate, see
Fig. 8-2)

• The unit must have a minimum of 14" right, left, and rear

clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10"
clearance between the sideburner and protected wall.)

C. Clearance between sideburner and combustible wall

• The unit must have a minimum of 18" right, left, and rear

clearance from any combustible wall (see Fig. 8-3).

Backsplash (if applicable)

If a non-combustible backsplash exists, it must have a minimum
of a 4" clearance from the rear of the unit (to allow for proper
ventilation and prevent dangerous overheating). See Fig. 8-4.

Important: This 4" backsplash clearance must fi rst be met prior

to any non-combustible walls beginning behind it.

Fig. 8-1 Clearance 'A' Diagram

Fig. 8-2 Clearance 'B' Diagram

Fig. 8-3 Clearance 'C' Diagram

Non-combustible

Min.

4"

(Clearance required for

right, left, and rear)

Min.

14"

Non-combustible

substrate

Non-combustible 4"

Combustible

Min.

18"

(Clearance required for

right, left, and rear)

(Clearance required for

right, left, and rear)

Fig. 8-4 Backsplash clearance

Non-combustible

Backsplash

Min.

4"

Com-

bustible