Air shutters are preset at the factory based on the 
gas the sideburner is built to burn. However, altitude 
or other local conditions may require air shutter 
adjustment for proper combustion. 
The fl ames from a properly adjusted sideburner 
will touch the burner ports and appear mostly blue. 
If they are orange, “lazy,” or lift off the burner ports, 
then adjust the sideburner air shutter using the 
following steps.
The air shutter is located at the end of the burner 
assembly, behind the control panel. It can safely 
and easily be adjusted while the unit is lit.
CAUTION: D o n o t t o u c h t h e s i d e bu r n e r
surrounding top area, as it will be 
hot while adjusting the air shutter.
1. Remove the control knob and screws fi rst, then
carefully lift away the control panel.
Important: Prior to fully removing the control
panel, you must disconnect the 
battery holder assembly wires that 
are located behind the control panel.
2.
Replace the control knob back on to the valve
stem.
3. Light the sideburner following the LIGHTING
INSTRUCTIONS section.
4. Loosen the front burner air shutter adjustment
screw, then use the tip of a screwdriver to open 
or close the air shutter until the fl ames appear 
blue and touch the burner ports.
5. Retighten the adjustment screw.
6. Once adjustment is complete; be sure the
unit is off and remove the knob, then replace 
the control panel, being sure to reconnect 
the battery holder assembly wires. Replace 
the control knob.
Close
Open
AIR SHUTTER ADJUSTMENT
Fig. 14-2 Air shutter adjustment