Air shutters are preset at the factory based on the
gas the sideburner is built to burn. However, altitude
or other local conditions may require air shutter
adjustment for proper combustion.

The fl ames from a properly adjusted sideburner
will touch the burner ports and appear mostly blue.

If they are orange, “lazy,” or lift off the burner ports,
then adjust the sideburner air shutter using the
following steps.

The air shutter is located at the end of the burner
assembly, behind the control panel. It can safely
and easily be adjusted while the unit is lit.

CAUTION: D o n o t t o u c h t h e s i d e bu r n e r

surrounding top area, as it will be
hot while adjusting the air shutter.

1. Remove the control knob and screws fi rst, then

carefully lift away the control panel.

Important: Prior to fully removing the control

panel, you must disconnect the
battery holder assembly wires that
are located behind the control panel.

2.

Replace the control knob back on to the valve

stem.

3. Light the sideburner following the LIGHTING

INSTRUCTIONS section.

4. Loosen the front burner air shutter adjustment

screw, then use the tip of a screwdriver to open
or close the air shutter until the fl ames appear
blue and touch the burner ports.

5. Retighten the adjustment screw.

6. Once adjustment is complete; be sure the

unit is off and remove the knob, then replace
the control panel, being sure to reconnect
the battery holder assembly wires. Replace
the control knob.