Installation requirements – Fire Magic Diamond Single Sideburner 32794-1 Series User Manual
Page 9

9
Installation must be performed by a qualifi ed professional
service technician.
This unit is designed for outdoor use only. DO NOT use this unit
inside a building, garage, or enclosed area.
See below for details on installing under overhead
construction.
DO NOT use this unit in or on a recreational vehicle or boat.
Important: If installing this unit in a combustible enclosure, the
correct air gap requirement must be met.
Important: Refer to the information below to ensure all
required clearances are met.
The unit must have a minimum clearance of 18" from
combustible materials/items AT ALL TIMES.
Overhead Construction Requirements (if applicable)
A 6 foot clearance is required between the countertop and the
construction above (Fig. 9-1).
Side and Rear Wall Clearances
For the minimum clearances between the sideburner and any
side or rear walls, your setup must fall within one (or more) of
the following:
A. Clearance between sideburner and strictly non-
combustible wall
(i.e. brick wall, see Fig. 9-2)
• The unit must have a minimum of 4" right, left, and rear
clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)
B. Clearance between sideburner and a protected
combustible wall
(i.e. a non-combustible wall in front of a combustible wall to
serve as a barrier. This can be accomplished by brick, or
a metal stud fi nished with non-combustible substrate, see
Fig. 9-3)
• The unit must have a minimum of 14" right, left, and rear
clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10"
clearance between the sideburner and protected wall.)
C. Clearance between sideburner and combustible wall
• The unit must have a minimum of 18" right, left, and rear
clearance from any combustible wall (see Fig. 9-4).
Backsplash (if applicable)
If a non-combustible backsplash exists, it must have a minimum
of a 4" clearance from the rear of the unit (to allow for proper
ventilation and prevent dangerous overheating). See Fig. 9-5.
Important: This 4" backsplash clearance must fi rst be met prior
to any non-combustible walls beginning behind it.
INSTALLATION REQUIREMENTS
Min.
14"
Min.
18"
Min.
4"
Fig. 9-2 Clearance 'A' Diagram
Fig. 9-3 Clearance 'B' Diagram
Fig. 9-4 Clearance 'C' Diagram
Non-combustible
Non-combustible
substrate
Non-combustible 4"
Combustible
(Clearance required for
right, left, and rear)
Fig. 9-5 Backsplash clearance
Non-combustible
Backsplash
Com-
bustible
(Clearance required for
right, left, and rear)
(Clearance required for
right, left, and rear)
Fig. 9-1 Overhead requirements
Min.
4"
Min.
6'
Combustible construction:
Requires vent hood or protection kit
Non-combustible construction:
Okay as-is
REV 2 - 1502100745
L-C2-378