Top view front view, Model specifications (cont.), Substrate – Fire Magic Diamond Single Sideburner 32794-1 Series User Manual
Page 6: Combustible enclosure cut-out

6
SUBSTRATE
When adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:
Substrate Behind Control Panel
Substrate Alongside Control Panel
C
C
Flush
(Control panel)
(Countertop)
(Countertop)
(Control panel)
Substrate
(includes tiles,
etc. at front of
enclosure)
Countertop
overhang
(if applicable)
Flush
Sideburner
liner
Substrate
(includes tiles,
etc. at front of
enclosure)
1
/
4
"
Clearance
Any additional substrate alongside the control panel
does not need to be considered in Dim. C (see previous
page), however a
1
/
4
" clearance on each side (same as
overhang) and below is required.
Substrate + countertop "front to back" cutout
must equate to Dim. C (see previous page)
when the substrate sits fl ush behind the
control panel.
Fig. 6-2
Fig. 6-3
Countertop
overhang
(if applicable)
TOP VIEW
TOP VIEW
1
/
4
"
Clearance
COMBUSTIBLE ENCLOSURE CUT-OUT
This unit may be installed into combustible framing (wood, for instance) provided there is a minimum of a
1
/
2
" airspace between ALL sides of the unit and any combustible material.
TOP VIEW
FRONT VIEW
Stainless
steel
hanger
Fig. 6-1
(Sideburner)
Countertop
Countertop
Countertop
(Sideburner)
Stainless
steel
hanger
Maintain air gap all the way down
(sides and rear) below countertop
Edge of
counter
cut-out
1
/
2
"
AIR GAP
1
/
2
"
AIR GAP
1
/
2
" min.
air gap to all
combustible
material
MODEL SPECIFICATIONS (cont.)
Sideburner
liner
REV 2 - 1502100745
L-C2-378