ELECTRICAL CONNECTIONS
A 120VAC (15 AMP minimum) Ground Fault Circuit
Interrupter (GFCI) GROUNDED 3-wire receptacle (not
included) is required within the vicinity of the grill to provide
power to the unit.
• Observe all local codes.
• Verify proper polarity of the receptacle.
• If an extension cord is used, ensure it is a 3-wire
GROUNDED cord that is rated for the power of the
equipment, and is approved for outdoor use with
a W-A marking. DO NOT use 2-prong adapters.
• DO NOT TAMPER WITH THE EXTENSION CORD
OR THE UNIT POWER-SUPPLY CORD.
LIGHT SWITCH
The light switch is push button operated, and is located on
the right side of the control panel (see Fig. 8-1). It controls
the power to the lighted knob and igniter . It allows the
power to be turned on or off for safety and convenience.
The switch will need to be turned on prior to each use, and
turned off after each use.
1. The sideburner and surrounding area MUST
remain clear of fl ammable substances such as
gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
3. When using propane gas:
a. The required ventilation openings in the
enclosure must be clear of debris.
b. The propane cylinder, regulator, and rubber
hose must be in a location not subject to
temperature above 125° F (51° C).
4. The fl ames on the burner burn evenly along the
burner cap with a steady fl ame (mostly blue). If
burner fl ames are not normal, check and clean
the orifi ce and burner/venturi tube for insects
and insect nests. A clogged tube can lead to a
fi re beneath the unit. A proper fl ame pattern will
ensure safe operation and optimal performance.
Adjust the air shutter as needed (see AIR
SHUTTER ADJUSTMENT).
5. The in-line gas valve or gas cylinder valve must
always be shut OFF when the unit is not in use.
6. Do not operate the burner with the cover in
place.
7. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male
connector, then make the connection.
WARNING: NEVER cover more than 75% of the cooking surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The unit serial identifi cation number and rating label are located on the inside of the
control panel. The unit must be completely cool before opening.
MAINTENANCE AND SAFETY INFORMATION
Light
switch
Fig. 8-1
REV 2 - 1502100745
L-C2-378