beautypg.com

Permanent gang option, Iv. permanent gang option – DNF Controls SW1X8 User Manual

Page 6

background image

Page

4

4

o

o

f

f

1

1

2

2

SW1X8, RS422 Switcher

IV.

PERMANENT GANG OPTION

When the PERMANENT GANG Software option is included in the SW1X8,
the following functionality is changed as follows:

When a gang is created, it is Permanent (until the operator clears the

gang).

Example: Gang Outputs [1], [2] and [3].

Output 1 LED blinks.
Output 2 & 3 LEDs stay on solid.


Select Output [5].

Only Output #5 LED is on and blinks.

Select Output [1], [2] or [3].
All of the members of the gang have their LEDs on.
Output 1 blinks.


To CLEAR old gang and create a new one:

Press and hold any key, then select the other keys to be
ganged.

While holding the master of the gang (the key with the blinking LED), it is

now possible to toggle members in and out of the gang.

Example: Gang outputs [1], [2] and [3].

Output 1 LED blinks.
Output 2 and 3 LEDs stay on solid.

Release all keys.

Press and hold Output [1]; the gang master LED blinks.

Press any key: It becomes a member of the gang.
Press it again and it is removed from the gang.