Digi-Star EZ3400(V) User Manual
Page 32
List with direct access numbers
D3714-GB Rev B EZ3400(V) User' s manual
28
Setting
[display]
Access
Nº
Options [displayed]
(bold=default)
Description
MENU 3. CALIBRATION SETTINGS WEIGHING INDICATOR
DISPLAY UNIT
[
lb-kg]
303
LB/KG
Display in lb or kg.
MENU 4. PRESET, RECIPE & COUNTER FUNCTIONS
PREALARM
[
P MTHD] & [P-ALM]
401
WEIGHT
PERCENT
Select WEIGHT or PERCNT and
enter a value to activate an early
warning indicating that the weighing
indicator is reaching the preset
amount.
SIREN
[BUZZER]
404
1-4, ON/OFF
Switching the loud alarm signal ON
or OFF.
TIMER/COUNTER
[
TMRCTR]
421
REV.
TIME
Determination of the recipe mixing
time based on time or on the
number of mixing auger revolutions.
DRIVE RATIO
[
DRATIO]
422
0001.00
The number of input impulses (PTO
revolutions), which correspond with
one single revolution of the mixing
auger.
TOLERANCE
[
TOLER]
442
OFF,.5,1-5,7,10
The tolerance (percentage of the
ingredient amount) to accept the
ingredient.
INGR. ADVANCE DELAY
[
DELAY]
443
MANUAL, 1-3,5,7,
10,20,30,60
The number of seconds the
weighing indicator should wait
before automatically advancing to
the next ingredient.
USER ID
[
USERID]
446
ON/OFF
If this setting is
ON, the operator
should enter the user ID to use the
weighing indicator.
RECIPE TOTAL
[
RECTOT]
451
ON/OFF
Displayed total weight of the recipe
to be loaded.
TOLERANCE OVERLOCK
[
OVERLK]
453
ON/OFF
If this setting is
ON, the weighing
indicator does not automatically
advance to the next ingredient when
exceeding the set tolerance.