Rssmin), Rsstol), Rsstdy) – Digi-Star GT460 User Manual
Page 34

Setting Options
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
Preset Active
Signal
Timeout
(PAST)
475
Enter XX:XX
Time to continue preset
active signal after preset is
reached. See page 36.
Unload
Weight
Displayed
(UNWEDI)
476
NET
GROSS
LOAD
See page 36.
Auto Load
Preset
(ALP)
477
OFF,
STORED,
TRUCK, PARTCP
See page 37
MENU 5. CONTROL SETTINGS
RPM Start
/Stop
(RSSCTL)
531
ON
ON enables automatic
start/stop feature using
RPM sensor on PTO shaft.
RPM Stop
Speed
(RSSMIN)
532
300
Set to 20%-50% of PTO
operating RPMs. Stop is
activated using this value.
RPM Start
Tolerance
(RSSTOL)
533
100
Set to 10% of PTO
operating RPMs. Start is
activated using this value
added to DAN 532 (400)
RPM Start
Delay
(RSSTDY)
534
2
Time in seconds. Start is
activated when RPMs are
above DAN 532 + DAN 533
for this period.
RPM Stop
Delay
(RSSPDY)
535
2
Time in seconds. Stop is
activated when RPMs are
below DAN 532 for this
period.
CALIBRATION
Setup
Number
(
SETUP
)
871
Quick entry method selects
weigh method 1-4lbs, 5-
8kg, gain 1-9, display
counts 1-9 and capacity
*1000.
34
GT460 AutoLog
2
Operators Manual
D3804