Chapter 3
Power Failure Control
This section is used to control the status when the power failures.
Control the status when
power loss occurs.
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Version 2.15.1226. Copyright (C) 2012 American Megatrends, Inc.
Power Failure Control
Power-Loss State (by SIO)
Advanced
[Always off]
WatchDog Count Mode
Selection.
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Version 2.15.1226. Copyright (C) 2012 American Megatrends, Inc.
WatchDog Parameters
WatchDog Count Mode [Second]
WatchDog TimeOut Value
0
Advanced
WatchDog Count Mode
This field is used to select the WatchDog count mode.
WatchDog TimeOut Value
This field is used to fill the WatchDog timeout value. 0 means disabled.
Select Screen
Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous
Values
F3: Optimized
Defaults
F4: Save & Exit
ESC: Exit
Power-Loss State (by SIO)
Always Off
When power returns after an AC power failure, the system’s power is off. You
must
press the Power button to power-on the system.
Always On
When power returns after an AC power failure, the system will automatically power-on.
Keeps Last State
When power returns after an AC power failure, the system will return to the state
where you left off before power failure occurs. If the system’s power is off when AC
power failure occurs, it will remain off when power returns. If the system’s power is on
when AC power failure occurs, the system will power-on when power returns.
WatchDog Configuration
This field sets system WatchDog parameters.
Select Screen
Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous
Values
F3: Optimized
Defaults
F4: Save & Exit
ESC: Exit