beautypg.com

Installation, Model 8p-mas page 6, Master and switched ports – Dataprobe 8P-MAS User Manual

Page 6: Pin # designation, Rts / dtr selection, Figure 3, Figure 2, Component location, System diagram

background image

Model 8P-MAS

Page 6

INSTALLATION

Master and Switched Ports

Connection to the Switched A-H ports is made using 25 pin D Subminiature connectors on the rear of
the unit. The following leads are supported for Asynchronous communications:

Pin # Designation

2

Transmit Data

3

Receive Data

4

Request to Send

5

Clear to Send

6

Data Set Ready

7

Signal Ground

8

Data Carrier Detect

20

Data Terminal Ready

The eight switched ports A-H are wired DCE (output
data on pin 3,RD). The Master port is wired for as DTE.
To directly connect a terminal device to the Master
Port, a Null cable is required. Refer to Figure 4 below.

RTS / DTR Selection

Jumpers JP1 through JP8 allows selection of RTS or DTR as the control lead used in the Lead Control
mode. To access these jumpers, disconnect the power source and remove the top cover of the 8P-
CAS by loosening the two screws on the underside of the unit. The jumpers are located as shown
below on Figure 3.

Figure 3

Component Location

Typical
Port A-H

RTS
Mon.

Switch
Control

Code
Mon.

Electronic
4 Way
Switch

2 TD

3 RD

4 RTS

5 CTS
6 DSR
8 DCD

DTR

20

7 SG

2 TD

3 RD

4 RTS

5 CTS
6 DSR
8 DCD

DTR

20

7 SG

Master
Port

Figure 2

System Diagram

DTR

RTS

This manual is related to the following products: