beautypg.com

Dataprobe 8P-MAS User Manual

Page 4

background image

Model 8P-MAS

Page 4

CURRENT LABEL PORT A PORT A

NEW LABEL PORT A > Your New Name

PORT LABEL CHANGED FROM: PORT A

TO: Your New Name

SAVE CHANGES? (Y/N) >

Password

To change the password, it must be reentered. Then a prompt for a new password, then a confirmation
of the new password. The password may be up to eight characters and is case sensitive.

LOGIN > TEST

ENTER NEW PASSWORD > TEST

RE-ENTER NEW PASSWORD > TEST

PASSWORD CHANGED

Please remember you password. If you forget your password, the unit needs to be returned to
Dataprobe for re-initialization. There is a charge for this.

Set Baud Rate

ENTER BAUD >

Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200
This changes only the default speed. The Auto Rate Detector can always be invoked by sending the
Enter Key several times.

Set Character Format

ENTER N,E,O >

Enter only the Parity, N, E or O for None, Even, Odd respectively. The 8P-MAS will automatically
adjust for the number of data bits and 1 stop bit.

Set for Lead Control Yes or No

ENTER Y/N >

Enter Y to add RTS/DTR Lead control to the 8P-MAS. This mode allows the RTS or DTR of Ports A
through H to select the Master Port. Change this setting to Yes if you require one or more of the
devices connected to ports A through H to be able to dial out through the modem on the Master Port.
below for a detailed description of Lead control.

This manual is related to the following products: