Diagnostics and Troubleshooting

34

 

One row of modules is not working or shows a distorted message

• Check/replace the ribbon cables to and from the first non-working module.
• Check for bent pins on the jack going to a non-working module.
• Move or replace the modules that show distorted text.
• Move or replace the last working module.
• Make sure that the first module in the row is receiving power.

A column of the display does not work.

• Check that the ribbon and power cable are plugged into the first module in the row.
• While power is on, look at the back of the first malfunctioning module to see if the

diagnostic LED is off, implying a power supply problem.

Entire display fails to work

• Check diagnostic LEDs on the controller for Power and Run. (Section 7.1)
• Check the breakers in the building connected to main power source.
• Check the breakers in the power termination panel.
• Check/replace the ribbon cable(s) from the controller to the modules.
• Verify proper use of the software by checking the software manual.

Brightness problems

Display is stuck on bright or dim

• Check Manual/Auto dimming in Venus 1500 software. The Brightness is typically set to

Automatic. If not, perform the following step:
> In Display Manager/ Diagnostics, change the slide bar and click Set Brightness.

• Check the light sensor cable and wiring for secure connections.
• Check the light sensor lens for obstructions (top left edge, front of primary cabinet).
• Replace the light sensor assembly.

Display is too bright at night
Set the Dimming Schedule. Refer to the Venus 1500 manual.

Message problems

Blank display seen after boot-up
A blank display is normal after the boot-up procedure. When finished, the display will be
blank except for a flashing LED in the lower right corner. The display is then waiting for
a message to be sent.

LED flashes in the lower right corner
The flashing pixel indicates that the display is receiving power and waiting for a message
to be sent. Once a message is sent, the flashing LED should be replaced with the message.

Message only shows up on one side of the display

• Check/replace ribbon cables from the last module on Face A to the first module in

Face B (Figure 35).

• Move or replace the first non-working module.
• Move or replace the last working module in Face A.
• Check that the power LED is on at the back of the modules.
• Make sure the power cable to the module is connected.