Appendix a technical specifications – Comtech EF Data RCU108 User Manual
Page 33

RCU108 1:8 Protection Switch
Specifications
TM066 - Rev. 1
A-1
Appendix A
Technical Specifications
Front Panel Display
Indications:
Online, Backup, Fault, Manual (Primary Converters)
Online, Standby, Fault, Error (Backup Converter)
Controls:
Manual + Set/Reset Pushbuttons
Backup Configuration
Menu: (via backup converter):
Converter ID#: 1 through N (RS485 Equipment Address)
Priority: 1 (highest) through N and 0 (none)
Converter Priority:
(Via Backup Converter front panel or serial port):
Frequency, Gain, Status, Fault Isolation
Rear Panel:
BU INTFC 1-8 & BU
D Sub, 15-Pin Socket (J17- J24)
RF In/Out
SMA-F
IF In/Out
BNC-F
Summary/Fault Status D Sub, 15-Pin socket (J6)
RS485
D Sub, 9-Pin (J1)
Switch Transfer Specifications:
Bandwidth
DC-18 GHz
Insertion Loss (Online) 0.4 dB C-band, 0.5 dB, Ku-band
Insertion Loss (Backup) 0.8 dB x N
Impedance
50 Ohms
VSWR
1.5:1 Maximum
Isolation
70 dB min.
Switch IF Ports:
Bandwidth
50-180 MHz
Insertion Loss
0.2 dB
Impedance
75 ohms
VSWR
1.3:1
Isolation
80 dB
Mechanical:
Size:
19” x 3.5” x 19” deep
Weight
8 Lbs. (1:8)