beautypg.com

Comtech EF Data RCU108 User Manual

Page 26

background image

Operation

RCU108 1:8 Protection Switch

Page 3-4

TM066 - Rev. 1

3.3

Switch Menu

For a 1:8 Backup Converter, the Menu will appear as follows:

{MENU} for Main Menu

{ENTER} for Switch Menu

3.4

Switch Configuration Menu

CONV

1 2 3 4 5 6 7 8

PRI

0 0 0 0 0 0 0 0

This Menu is applicable for a 1:8 Backup Converter. It allows the operator to specify the priority of the
various converters.

0 = No Priority - The Backup will ignore the Prime.

1 = Highest Priority, 8 = Lowest Priority.

The Arrow keys are used to move left and right and increase/decrease a converter’s priority. When
all of the priorities have been set, pressing the Enter key causes the Backup to accept the entries and
store them in non-volatile RAM. Pressing the Menu key will scroll to the next menu.

3.5

Learn Menu (Backup Converter Only)

{MENU} for next menu

{ENTER} for Learn Mode

Depressing

will scroll to the Utilities Menu. Depressing will cause the Backup
Converter to ‘Learn’ about the Primary Converter. The screen automatically scrolls to the ‘Learn
Status’ menu.

3.6 Learn Status Menus (Backup Converter Only)

Automatic Learning

In Progress

The ‘Automatic Learning in Progress’ window indicates that the Backup Converter is polling the Prime
Converters in order to learn about them.