6

DSR----to pin 4

DSR ---to pin 4

2

7

RTS----to Pin 8

RTS----to Pin 8

4

8

CTS----to pin 7

CTS----to pin 7

6

9

N/C

TXData\

8

NOTE: In order to obtain these signals at the output connector, the jumper configuration on the
AS/3048 Controller PWB must have been performed as outlined in Appendix B. A summary of
jumper selections is as follows:

Configuration

JP4-1

JP4-2

JP4-3

JP4-4

JP4-5

JP4-6

JP3

JP5

JP6

JP7

JP8

RS232

OUT

OUT

OUT

OUT

IN

IN

OUT

OUT

IN

OUT

OUT

RS422

IN

IN

IN

IN

OUT

OUT

OUT*

OUT

OUT

OUT

IN

RS485

IN

IN

IN

IN

OUT

OUT

OUT*

OUT

OUT

OUT

IN

485 1/2 DPLX

IN

OUT

OUT

IN

OUT

OUT

OUT*

IN

OUT

IN

IN

* Receiver terminations for twisted pair RS422/485 can be optionally terminated at 120 ohms by
installing JP3. Factory-supplied cables for multiple converter "daisy chain" operation are