Configuration – Comtech EF Data CPLINK User Manual

Page 10

background image

8

5. Configuration

Main Menu > Configuration (Ref: Fig. 5)

Configuration…


There are five (5) configuration modes to choose from:

# System Type: Selects between a standalone system (1 transceiver) and a 1:1

redundant system.


# Signal Path: Select Signal Path to view and change the Upconverter Frequency.

Upconverter Amplifier attenuation (00.00-20.00 dB), Amp ON/OFF,
Mute ON/OFF, Downconverter Frequency, Downconverter
Frequency, Downconverter Attenuation (00.00-20.00 dB), Mute
ON/OFF XCVR parameters.


# LNA: Select LNA to view and change Current Source ON/OFF, XCVR Fault Logic

ON/OFF, the allowable Current Window, and the percent Current change.
Reference the menu item LNA
Configuration for additional
information.


# Miscellaneous: Select Miscellaneous to

view or change Cold Start,
Auto Fault Recovery
(AFR), Local Reference
Oscillator Adjustment,
External Reference Fault
Logic, and Up and Down
converter slope
adjustments.


# Redundancy Controller: Online Unit

(XCVR) selector,
Operating Mode
AUTO/MAN, Waveguide
Switch Status OK/FT,
Controller Voltages
monitoring +5VDC and +12VDC.




Fig. 5