Configuration – Comtech EF Data CPLINK User Manual
Page 10

8
5. Configuration
Main Menu > Configuration (Ref: Fig. 5)
Configuration…
There are five (5) configuration modes to choose from:
# System Type: Selects between a standalone system (1 transceiver) and a 1:1
redundant system.
# Signal Path: Select Signal Path to view and change the Upconverter Frequency.
Upconverter Amplifier attenuation (00.00-20.00 dB), Amp ON/OFF,
Mute ON/OFF, Downconverter Frequency, Downconverter
Frequency, Downconverter Attenuation (00.00-20.00 dB), Mute
ON/OFF XCVR parameters.
# LNA: Select LNA to view and change Current Source ON/OFF, XCVR Fault Logic
ON/OFF, the allowable Current Window, and the percent Current change.
Reference the menu item LNA
Configuration for additional
information.
# Miscellaneous: Select Miscellaneous to
view or change Cold Start,
Auto Fault Recovery
(AFR), Local Reference
Oscillator Adjustment,
External Reference Fault
Logic, and Up and Down
converter slope
adjustments.
# Redundancy Controller: Online Unit
(XCVR) selector,
Operating Mode
AUTO/MAN, Waveguide
Switch Status OK/FT,
Controller Voltages
monitoring +5VDC and +12VDC.