SDM-300L Satellite Modem

Operation

Rev. 2

3–11

SDM300L "TYPE"

VER: X.X.X

FUNCTION SELECT

CONFIGURATION

CONFIGURATION

LOCAL AUPC

(AUPC option only)

AUPC ENABLE

NOMINAL POWER

MINIMUM POWER

MAXIMUM POWER

TARGET NOISE

TRACKING RATE

LOCAL CL ACTION

REMOTE CL ACTION

ON

OFF

-5.0 to -30.0 dBm

(In 0.5 dBm steps)

[0 to -40.0 TX/RX L-Band Only]

3.2 to 16.0 dB

(In 0.1 dB steps)

0.5 to 6.0 dBm/min

(In 0.5 dBm/min steps)

HOLD

NOMINAL

MAXIMUM

-5.0 to -30.0 dBm

(In 0.5 dBm steps)

[0 to -40.0 TX/RX L-Band Only]

-5.0 to -30.0 dBm

(In 0.5 dBm steps)

[0 to -40.0 TX/RX L-Band Only]

HOLD

NOMINAL

MAXIMUM

ACCESS TO

SUBMENU

CONDITIONAL OR

OPTION-DEPENDENT

Parameter Information

Key:

Figure 3-7. Configuration Local AUPC Menu

Notes:

1. Used for ASYNC/AUPC option and for self-monitoring local AUPC control.
2. Manufacturer does not recommend the tracking noise ( E

b

/N

0

) be set within 15.5 and 16.0 dB.