Delta DT3 User Manual

Page 3

background image

3

ALARM1 LOW: Lower limit alarm 1 (display according to the setting in ALARM mode)

4.0

ALARM2 HIGH: Upper limit alarm 2 (display according to the setting in ALARM mode)

4.0

ALARM2 LOW: Lower limit alarm 2 (display according to the setting in ALARM mode)

4.0

ALARM3 HIGH: Upper limit alarm 3 (set OUT2 to ALARM mode and it will display according to the

setting in ALARM mode)

4.0

ALARM3 LOW: Lower limit alarm 3 (set OUT2 to ALARM mode and it will display according to the
setting in ALARM mode)

4.0

ALARM1 HIGH PEAK: High peak value 1

ALARM1 LOW PEAK: Low peak value 1

ALARM2 HIGH PEAK: High peak value 2

ALARM2 LOW PEAK: Low peak value 2

ALARM3 HIGH PEAK: High peak value 3 (display when OUT2 is set to alarm mode)

ALARM3 LOW PEAK: Low peak value 3 (display when OUT2 is set to alarm mode)

OUT1: Display and adjust output value of 1

st

output group

0.0

OUT2: Display and adjust output value of 2

nd

output group (display when OUT2 is set to

Heating/Cooling Mode)

0.0

OUT1 MAX: Upper limit % of 1

st

output group (perform linear calculation again)

100.0

OUT1 MIN.: Lower limit % of 1

st

output group

0.0

OUT2 MAX: Upper limit % of 2

nd

output group (display when OUT2 is set to Heating/Cooling Mode)

100.0

OUT2 MIN: Lower limit % of 2

nd

output group (display when OUT2 is set to Heating/Cooling Mode)

0.0

CT1: Display CT1 current (display when external CT is connected to CT1)

CT2: Display CT2 current (display when external CT is connected to CT2)

press

to return to target temperature setting.


Initial Setting Mode】Parameter Settings:

Display

Description

Factory Setting

INPUT: Set input type (refer to “Temperature Sensor Type & Temperature Range Chart” for the
selection of Thermocouple or Platinum Resistance types.)

PT

TEMP. UNIT: Set temperature unit /

℃ ℉(

it wil not be displayed when in analog input mode)

TEMP. HIGH: Set up upper temperature limit (the upper limit setting is different for different types of
sensor)

850.0

TEMP. LOW: Set up lower temperature limit (the lower limit setting is different for different types of
sensor)

-200.0

CONTROL: Select control modes ( 4 different modes: ON-OFF, PID, MANUAL, and FUZZY)

PID

CONTROL SV provides 4 different options: CONS; PROG; SLOP; and REMO. REMO mode is
available when REMOTE function is added.

CONS

WAIT SV: Set up waiting temperature (display when in programmable control)

WAIT TIME: Set up waiting time(display when in programmable control)

SLOP: Set up start slope (display when in programmable control)

PATTERN: Select pattern to be edited (display when in programmable control, there are 16 patterns

and each pattern includes 16 steps. Setting parameters are OFF, SAVE, 0~F.)

OFF

TUNE: Select AT or ST (display when in PID control mode)

AT

SELECT HEAT/COOL: Select heating, cooling or dual output heating and cooling

H1H2

ALARM1 SET: Set up Alarm 1 mode (refer to “Alarm Output” for more setting on modes)

0

ALARM1 OPTION:

Set up Alarm 1 options (refer to “Alarm Output” for more setting on modes)

0

ALARM1 DELAY: Set up Alarm 1 delay (refer to “Alarm Output” for more setting on modes)

0

ALARM2 SET: Set up Alarm 2 mode (refer to "Alarm Outputs")

0

ALARM2 OPTION: Set up Alarm 2 options (refer to “Alarm Outputs” )

0

ALARM2 DELAY: Set up Alarm 2 delay (refer to “Alarm Outputs” )

0

ALARM3 SET: Set up Alarm 3 mode (refer to "Alarm Output")(display when OUT2 is set to ALARM
mode)

0

ALARM3 OPTION: Set up Alarm 3 options (refer to "Alarm Output") (display when OUT2 is set to

0