Comtech EF Data QAM256 User Manual
Page 52
Product Options
QAM256 Digital Video Modulator and Upconverter
B-6
TM077 – Rev. 4.0
radQAM256TxMinorAlarm2Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bits
0..7
Spares
0 = Pass, 1 = Fail"
::=
{
radQAM256ModStatus
4
}
radQAM256TxCommonAlarm1Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit
0=Interface
hardware
fault
1=Fault
Bit
1=M&C
Hardware
Fault
Bit
2...7
Spares
0 = Pass, 1 = Fail"
::=
{
radQAM256ModStatus
5
}
radQAM256TxCommonAlarm2Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the
value
'00000000'B
Bits
0
..7
Spares
0 = Pass, 1 = Fail"
::=
{
radQAM256ModStatus
6
}
radQAM256TxLatchedMajorAlarm1Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit
0=Mod
Hardware
fault
Bit
1=Tx
Synthesizer
fault
Bit 2=Tx Data PLL lock fault
Bit
3=Tx
Framing
Lock
(Unused)
Bit 4=Mod Chip 1 Lock fault (Unused)
Bit 5=Mod Chip 2 Lock fault (Unused)
Bit 6=Mod Chip 3 Lock fault (Current chip used)
Bit
7=Spare
0 = Pass, 1 = Fail"
::=
{
radQAM256ModStatus
7
}
radQAM256TxLatchedMajorAlarm2Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"Bits
0
..7
Spares"
::=
{
radQAM256ModStatus
8
}
radQAM256TxLatchedMinorAlarm1Status
OBJECT-TYPE
SYNTAX
INTEGER
(0..255)
ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B
Bit
0=Clock
activity
detect
fault
Bit
1=Data
activity
detect
fault