Comtech EF Data QAM256 User Manual
Page 49

QAM256 Digital Video Modulator and Upconverter
SNMP MIB
TM077 – Rev. 4.0
B-
3
radQAM256TxClockPolarity
OBJECT-TYPE
SYNTAX
INTEGER {
normal(1),
inverted(2)
}
ACCESS
read-write
STATUS
current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock relative to Tx data."
::=
{
radQAM256ModNVStatus
12
}
radQAM256TxDataPolarity
OBJECT-TYPE
SYNTAX
INTEGER {
normal(1),
inverted(2)
}
ACCESS
read-write
STATUS
current
DESCRIPTION
"Selects
data
polarity"
::=
{
radQAM256ModNVStatus
13
}
radQAM256TxCarrierMode
OBJECT-TYPE
SYNTAX
INTEGER {
normal(1),
cw(2) }
ACCESS
read-write
STATUS
current
DESCRIPTION
"Normal sets the carrier to normal CW causes the modulator to output pure carrier"
::=
{
radQAM256ModNVStatus
14
}
radQAM256TxMajorAlarm1Mask OBJECT-TYPE
SYNTAX
INTEGER (0..255)
ACCESS
read-write
STATUS
current
DESCRIPTION
"Major
Alarm
1
mask:
Bit
0=Mod
Hardware
fault
1=Fault
Bit
1=Tx
Synthesizer
fault
Bit 2=Tx Data PLL lock fault
Bit
3=Tx
Framing
Lock
(Unused)
Bit 4=Mod Chip 1 Lock fault (Unused)
Bit 5=Mod Chip 2 Lock fault (Unused)
Bit 6=Mod Chip 3 Lock fault (Current chip used)
Bit
7=Spare
0 = Mask, 1 = Allow"
::=
{
radQAM256ModNVStatus
15
}
radQAM256TxMajorAlarm2Mask OBJECT-TYPE
SYNTAX
INTEGER (0..255)
ACCESS
read-write
STATUS
current
DESCRIPTION
"Major
alarm
2
mask:
Bits
0..7
=
spares
0=mask,
1=allow"
::=
{
radQAM256ModNVStatus
16
}
radQAM256TxMinorAlarm1Mask
OBJECT-TYPE
SYNTAX
INTEGER (0..255)
ACCESS
read-write
STATUS
current
DESCRIPTION
"Minor
Alarm
1
mask:
Bit
0=Clock
activity
detect
fault
Bit
1=Data
activity
detect
fault
Bit
2..7=Spares
0=Mask,
1=Allow"
::=
{
radQAM256ModNVStatus
17
}