SNMP MIB

TM077 – Rev. 4.0

B-

3

radQAM256TxClockPolarity

OBJECT-TYPE

SYNTAX

INTEGER {

normal(1),

inverted(2)

}

ACCESS

read-write

STATUS

current

DESCRIPTION

"Selects clock polarity for Tx terrestrial clock relative to Tx data."

::=

{

radQAM256ModNVStatus

12

}


radQAM256TxDataPolarity

OBJECT-TYPE

SYNTAX

INTEGER {

normal(1),

inverted(2)

}

ACCESS

read-write

STATUS

current

DESCRIPTION
"Selects

data

polarity"

::=

{

radQAM256ModNVStatus

13

}


radQAM256TxCarrierMode

OBJECT-TYPE

SYNTAX

INTEGER {

normal(1),

cw(2) }

ACCESS

read-write

STATUS

current

DESCRIPTION

"Normal sets the carrier to normal CW causes the modulator to output pure carrier"

::=

{

radQAM256ModNVStatus

14

}


radQAM256TxMajorAlarm1Mask OBJECT-TYPE
SYNTAX

INTEGER (0..255)

ACCESS

read-write

STATUS

current

DESCRIPTION
"Major

Alarm

1

mask:

Bit

0=Mod

Hardware

fault

1=Fault

Bit

1=Tx

Synthesizer

fault

Bit 2=Tx Data PLL lock fault

Bit

3=Tx

Framing

Lock

(Unused)

Bit 4=Mod Chip 1 Lock fault (Unused)

Bit 5=Mod Chip 2 Lock fault (Unused)

Bit 6=Mod Chip 3 Lock fault (Current chip used)

Bit

7=Spare

0 = Mask, 1 = Allow"

::=

{

radQAM256ModNVStatus

15

}


radQAM256TxMajorAlarm2Mask OBJECT-TYPE
SYNTAX

INTEGER (0..255)

ACCESS

read-write

STATUS

current

DESCRIPTION
"Major

alarm

2

mask:

Bits

0..7

=

spares

0=mask,

1=allow"

::=

{

radQAM256ModNVStatus

16

}


radQAM256TxMinorAlarm1Mask

OBJECT-TYPE

SYNTAX

INTEGER (0..255)

ACCESS

read-write

STATUS

current

DESCRIPTION
"Minor

Alarm

1

mask:

Bit

0=Clock

activity

detect

fault

Bit

1=Data

activity

detect

fault

Bit

2..7=Spares

0=Mask,

1=Allow"

::=

{

radQAM256ModNVStatus

17

}