Character Sets (OLIVETTI protocols)
CS000 – CS010 International, CS020 Germany, CS030 Portugal, CS040 Spain1, CS050 Denmark/Norway,
CS060 France, CS070 Italy, CS080 Sweden/Finland, CS090 Switzerland, CS100 Great Britain, CS110 USA
ASCII, CS140 Greece, CS150 Israel, CS170 Spain 2, CS200 Jugoslavia, CS410 Olivetti TCV 370, CS510
SDC, CS520 Turkey, CS540 CIBC, CS680 OLI-UNIX, CS701 PC-220 Spain2, CS711 PC-Denmark/Norway,
CS712 PC-Denmark OPE, CS771 PC-210 Greek
Barcodes
UPC/A, UPC/E, EAN8, EAN13, Code 39, Code 128, Postnet, Codabar, ADD-ON 2, ADD-ON 5, Code 11,
Code 93, BCD, MSI, 2/5 Interleaved, 2/5 Matrix, 2/5 Industrial
Interfaces
Parallel IEEE 1284 bidirectional, nibble and byte modes
Serial RS-232/C
Automatic Interface Switching
Serial Interface Signals
RTS
DCD
Female connector
5
9
4
8
3
7
2
6
1
Solder side
view
GND
To printer
CTS
To PC IBM
compatible
CTS
DSR
DSR
DTR
RX
DTR
Solder side
view
DCD
TX
RTS
GND
RI
Female connector
5
9
4
8
3
7
2
6
1
RI
RX
TX
Memory
64 Kbytes buffer
Special Functions
Automatic Gap Adjustment (AGA)
Auto Alignment
Auto Border Recognition