7 wp-8 installation – Cloud Electronics PS16 User Manual
Page 6
Pump Station 16-R: Installation and operation manual
5
7 WP-8
Installation
The WP-8 is a dedicated wall-mounting unit that has all of the
features of the RH-8 plus a provision for low power speakers.
The module is primarily aimed at applications such as tanning
suites and treatment rooms where users may wish to listen to
music. The WP-8 has two low impedance, low power speaker
outputs each with a different operation:
• The first is a normal low impedance speaker output.
• This second provides a similar low impedance output that is
disconnected when headphones are connected to the WP-8.
The WP-8 should be wired directly to the equipment rack using unscreened ‘Category 5’ cable
(4 pair CAT 5), an IDC insertion tool will be required to connect the WP-8 to the CAT-5 cable.
Cable length should not exceed 100m (328ft).
Cable for Hard Wiring a WP-8 to a Pump Station 16-R
Cable Information for Wiring the WP-8
WP-8 (IDC)
Pump Station 16-R (RJ45)
CAT 5*
Pin 1
Pin 8
Brown/White
Pin 2
Pin 7
White/Brown
Pin 3
Pin 6
Green/White
Pin 4
Pin 5
White/Blue
Pin 5
Pin 4
Blue/White
Pin 6
Pin 3
White/Green
Pin 7
Pin 2
Orange/White
Pin 8
Pin 1
White/Orange
*The CAT 5 colour is described as the dominant colour first with the tracer second.
The following diagrams show how to wire either speaker output in stereo or mono.
Permanent Speaker Network (Stereo) Switched Speaker Network (Stereo)
Permanent Speaker Network (Mono)
Switched Speaker Network (Mono)
16-07-02 V2.1