The room containing the cooker should have an air supply in accordance with BS.5540:
Part 2: 1989.
All rooms require an openable window or equivalent while some rooms require a perma-
nent vent in addition to the openable window.
The cooker should not be installed in a bed-sitting room, of volume less than 21 m

3

.

Where a DOMESTIC COOKER is installed in a room or internal space, that room or inter-
nal space shall be provided with a permanent opening which communicates directly with
outside air and is sized in accordance with table below. In domestic premises the perma-
nent opening shall be an air vent.
If there are other fuel burning appliances in the same room, BS.5540: Part 2: 1989 should
be consulted to determine the requisite air vent requirements.
If the cooker is installed in a cellar or basement, it is advisable to provide an air vent of
effective area 100 cm

2

, irrespective of the room volume.

(

) If the room or internal space containing these appliances has a door which opens

directly to outside, no permanent opening is required.

MINIMUM PERMANENT OPENING FREE AREA FOR FLUELESS APPLIANCE

5 m

3

to 10

m

3

Openable

window or

equivalent also

required

Maximum

appliance

rated input

limit

Room volume

11 m

3

to

20 m

3

> 20 m

3

< 5 m

3

Type of appliance

Domestic oven, hotplate,

grill or any combination

thereof.

None

50

(

)

cm

2

Nil

cm

2

Nil

cm

2

100

cm

2

Yes

Provision for ventilation