VII. MAINTENANCE
7.1 Flux belt must be properly adjusted, during operation, the latex flux belt should be snug and both roll
centerlines are parallel. Overly tight belt tension would cause the rollers to skew, bending both rollers and
cause the belt to roll off.
Flux belts are considered as consumables and should be replaced when it is worn or seriously burned.
7.2. Lubrication
Both SEW motors and reducers of the GIRTH WELDER drive system should be regularly lubricated, please
refer to SEW operating instruction manuals for detail maintenance instructions.
(See next page) The lubricant that is added to the equipment before they go out, can handle surrounding
temperatures of -10 to 50° (14 degrees to 122 degrees F). Once exceeding the range, please add proper