beautypg.com

BUG-O Systems CB-1P User Manual

Page 36

background image

36

EVERY TWELVE MONTHS:

Refer to CB-1P Exploded View Parts List. (Page 13)

1" Bearing with Fasteners Item # 21: Do not grease the bearing it is greased for life by the

manufacturer. If the grease fitting has not been removed and plugged we suggest that you do

so now. Earlier models may not have been plugged at time of assembly.

1-1/4" Bearing with Fasteners Item # 22: Do not grease the bearing it is greased for life by the

manufacturer. If the grease fitting has not been removed and plugged we suggest that you do

so now. Earlier models may not have been plugged at time of assembly.

P.M. Motor Assembly Item # 9: Bodine gear motor lubrication. Fill gear motor to oil level

indicator with worm gear oil conforming to AGMA#5EP compounded (SAE#90) oil or Bodine

lubricant #LO-23. Do not overfill.

Transmission 3.5:1 Assembly Item # 8: Inspect for excessive wear and tear. Keep the

transmission assembly clean and lubricate with Lubriplate #630-AA.

Refer to CB-1P Wiring Diagram. (Page 14)

CB-1P Collector: The collector ring should be sanded once a year. If the collector ring is

pitted too badly it should be replaced. Inspect all wires coming out of the collector ring for cut

or missing insulation. All wires should be fastened to the center shaft with a nylon cable tie.

Tighten four set screws if needed.

Manifold Power Cable: Ensure that the cable is fastened tightly to the large brush holder

and the manifold retainer. Inspect the cable for cut or missing insulation. Replace the cable if

necessary.

Manifold Retainer: Inspect for damage. Ensure that all cables and the oxygen hose are

fastened tightly. Inspect the cables and oxygen hose for cuts or missing insulation. Replace if

necessary.

Junction Box: Inspect the cables for cuts or missing insulation. Ensure that all terminal ends

and connections are snug. Replace if necessary.

Low Frequency Power Cable: Inspect the cable for cut or missing insulation. Ensure that the

micarta insulator is in good condition. Replace if necessary.

High Frequency Power Cable: Inspect the cable for cut or missing insulation. Ensure that the

micarta insulator is in good condition. Replace if necessary.