Broadata Communications 250E Series User Manual
Page 12

BCI 250E/260E User’s Manual
Broadcast Quality Video/Audio/Data Transport System
Broadata Technical Support, [email protected]
13
RS 422 Differential Serial Data
The 260E units transport differential data signals with
compatible Full Duplex RS-422 type devices. Note that
RS-422 does not support handshaking control signals.
Use the following steps when connecting data
transmission equipment:
1.
Connect your serial data cable to the user’s RS-422
device. (See Figure 2-5).
2.
Connect the other end of this cable to the front
panel RS-422 female terminal block connector of
the 260E TX unit.
3.
Repeat step 1 and 2 for the 260E RX unit.
Figure 2-6 (b) shows pin connections between the 260E
Series unit (as a DCE unit) and the user’s RS-422
device (as a DTE unit).
Figure 2-6 (b)
Pin Connections Between 260E Series Unit and User’s
RS-422 Device
TX +
User’s
Equipment
(DTE)
IN 1
IN 2
GND
OUT 1
OUT 2
260E
Unit
(DCE)
Ground
RX +
TX -
RX -