beautypg.com

Care and maintenance, Hydrostatic pumps, Hydrostat drive belt replacement procedure – Dixon 8000G Series User Manual

Page 34

background image

34

CARE AND MAINTENANCE

HYDROSTATIC PUMPS:

Before each use, check to be sure that the cooling fins of

the hydrostatic pumps are clean. Excessive accumulation

of oil, dirt, or trash may cause the pumps to overheat.

NEVER WASH ACROSS TOP OF RESERVOIR WITH

WATER OR STEAM. Fill reservoir as required per the

maintenance schedule listed in this book.

HYDROSTAT DRIVE BELT

REPLACEMENT PROCEDURE:

To remove hydrostat pump drive belt:

(The hydrostat pump drive is equipped with a spring

loaded belt take-up).

1.

Raise seat. (See instructions on Page 25).

2.

Remove hold down bolts from belt cover. Remove

belt cover.

3.

Rotate the spring loaded take-up idler towards the

left hand hydro pump to provide belt slack for

removal.

4.

Remove belt.

To install hydrostat pump drive belt:

1.

Rotate the spring loaded take-up idler towards the left

hand hydro pump.

2.

Install belt per diagram.

3.

Re-attach belt cover.

4.

Return the seat to the operating position.