23

Version P1.3 : 151012

Bluelab Dosetr

onic P

eridoser Kit

Bluelab Corporation Limited

Bluelab Corporation Limited

3.6 On Times

On times are how long you dose
for. Together with the “Off Times”
this allows the Dosetronic to make
small frequent changes to the
conductivity, pH and temperature
of your system.

Adjust on time so that 3+ doses
changes the actual value by 1 digit.
Adjust off time (following page) to a
little longer than the time it takes for
a dose to be mixed and the change
sensed by the probes.

1. Select On times

Press up and down keys to select
mode.

2. Select desired measurement and

value to change
To programme On Times select the
appropriate measurement.
Note: Selected value will be
brighter than other values
displayed.

3. Programme desired On Times

Press (or hold down) the value
increase/decrease buttons
to change the value you have
selected.

1

2

OO.53

OO.O1

cont

3

Nutrient

On times

Please record
your values
here for future
reference.

Temperature

On times

pH

On times

3

Note:

Continuous Mode

This allows you to set your nutrient pumps,
pH adjuster and/or heater/cooler to
work continuously until the values reach
the required reading. This is helpful for
temperature regulation when you want the
heater/cooler to start at one temperature
and run continuously until off temperature is
reached.

cont

Programmable from 0-10 minutes
in one second steps.

Note: Start with short on times and
adjust from there.