Belshaw Adamatic TG50 Thermoglaze User Manual
Page 32
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
26 MN-1720WM Thermoglaze
THE PUMP MOTOR WILL NOT RUN
Possible Causes
What To Do
The connection of the power cord to the power
source is faulty.
Make sure the power cord is fully plugged in to a
proper power source.
The circuit breaker has been tripped.
1. Disconnect from power.
2. Open electrical enclosure.
3. Reset circuit breaker.
4. Close electrical enclosure.
The rear panel is not installed properly
1. Reinstall the rear panel.
2. Make sure that the key attached to the rear
panel is inserted into the safety interlock switch.
NOTE
The glaze pump will not run with the rear panel
removed.
THE FILL HOSE IS LEAKING
Possible Causes
What To Do
Fill hose is leaking at the connection.
Hose bracket needs adjusting or tightening.
Fill hose is leaking near the pump.
Check for missing or damaged o-ring.