beautypg.com

Belshaw Adamatic TG50 Thermoglaze User Manual

Page 25

background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

Thermoglaze MN-1720WM

19

WARNING

Growth of organisms in gaps, crevices, glaze

pump, lines, or frame can result from

improper cleaning and can cause mild to

serious ill health.

WARNING

Donuts or filling may catch fire due to

improper cleaning and can cause serious

injury, burns, or death.

Assembly

1. Install the glaze pump body.
2. Install the drive gear impeller. Line up the

flat on the shaft with the flat in the impeller.

NOTE

Lubricate the pump body, shaft “o” ring and

gear impellers with food grade mineral oil.

3. Install the lay gear impeller.

4. Install the “O” ring into the glaze pump

cover. Make sure it stays in place and you do
not pinch it between the pump and cover. The
“O” ring may need to be stretched before
installing.