Thermoglaze MN-1720WM
25
CONVEYOR WILL NOT MOVE
Possible Causes
What To Do
Oven not to correct temperature yet.
Wait until the oven comes to temp.and the ready
light comes on.
Conveyor is jammed.
Check for obstruction in conveyor and remove.
Motor circuit breaker is tripped.
Push the black circuit breaker reset at bottom of
oven control panel.
GLAZER WILL NOT PUMP GLAZE
Glazer motor is not running.
Check to make sure the motor is running.
(See Pump Motor Will Not Run)
Glazer pump impellers are worn.
1. Disconnect power.
2. Replace impellers.
The rear panel safety key is not inserted in the
safety switch.
Make sure the rear panel safety key is inserted into
the safety switch.
GLAZE IS MISSING THE DONUTS ON ONE SIDE OF THE GLAZE SCREEN
Glazer or glaze trough is not level.
Adjust level of glaze trough by moving set collar.
Glaze pump is running too slow.
1. Disconnect from power.
2. Open Electrical Enclosure.
3. Turn glazer speed control clockwise.
4. Close Electrical Enclosure.