Operation instructions – Belshaw Adamatic EP18-24 Proofer User Manual
Page 8

Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
2
MN-1202EN
EP18/24/34 Econo Proofer OM
Operation Instructions
CAUTION
If water is spilled while filling the water
pan, thoroughly dry all surfaces including
the floor. Spilled water may cause serious
injury, loss of life, or damage to
equipment. Water may continue to drip.
To prevent the floor from becoming wet
and slippery, use a pan to collect dripping
water. Do not move the proofer when
water is in the reservoir.
(Note: Use only distilled or purified water in
Proofer to avoid build-up in the water box of
minerals and deposits normally found in tap
water.)
1. Lift off water reservoir cover and fill water
reservoir (see Figure 3). If necessary, open
lower door(s) and remove screen(s) or
tray(s) to access the water reservoir. Do not
fill beyond ½” of the top edge. When
finished replace cover and doors.
Note: Do not pull the control box out to gain
access to the water reservoir because water
may be spilled when moving the control box.
2. Turn on control box power switch.
3. Set heat control to desired temperature.
4. After proof box is up to temperature, turn
humidity control to high. When desired
humidity has been achieved, turn humidity
control down to a midpoint setting. NOTE:
final optimum settings of both heat control
and humidity control can only be determined
through daily use of the proof box.
FIGURE 3