1 operation, Control functions – Belshaw Adamatic EP18-24 Proofer User Manual
Page 7

Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
EP18/24/34 Econo Proofer OM
MN-1202EN
1
1 Operation
Control Functions
SEE FIGURE 2, Following
:
A. HUMIDITY CONTROL PILOT
LIGHT: Indicates when the water
heater element is heating.
B. HUMIDITY CONTROL: Control for
the water heating element. Set on high,
the water heat element will remain on
constantly. Set on any setting other than
high, the control will cycle on and off.
Higher numbered settings create a longer
on-cycle and high humidity.
C. WARNING – LOW WATER PILOT
LIGHT: Indicates whenever the water
in the water reservoir is getting low. At
the same time this pilot light comes on, a
buzzer will go off, and power to the
water heating element is automatically
turned off. NOTE: This will result in a
drop or loss of humidity in the proof box.
D. HEAT CONTROL: Control for the air
heating element.
E. HEAT CONTROL PILOT LIGHT:
Indicates when the air heat element is
heating.
F. CONTROL BOX POWER SWITCH:
Controls the power to the control box.
G. CONTROL BOX POWER PILOT
LIGHT: Indicates the power in the
control box is on.
CAUTION
Do not permit water pan to run out of
water. Check often. Use only soft or
distilled water in the operation of this
proofer.
Figure 2