EP18/24/34 Econo Proofer TS

MN-1203EN

5

THE PROOF BOX WILL NOT HEAT UP

Possible Causes

What To Do

Control box power switch is not on.

Flip switch to on position.

Defective heat control.

Replace the heat control.

Loose wire or bad connection.

Repair the wire.

Defective heat element.

Replace the heat element.

Defective control box power switch.

Replace power switch.

LACK OF HUMIDITY OR UNEVEN HUMIDITY

Possible Causes

What To Do

Low water.

Refill water reservoir.

Defective humidity control.

Replace the humidity control.

Defective snap disc thermostat.

Replace the snap disc thermostat.

Defective water heat element.

Replace the water heat element.

Restriction or sediment in the water line or
the water heat box inlet hole.

Clean out water line.

Loose wire or bad connection in humidity
circuit.

Repair loose wire or connection in
humidity circuit.

Blower is not running.

See “Blower Will Not Run” section

Doors out of alignment.

Align doors.