Start-up – Beisler 1282-4 User Manual
Page 35
![background image](https://www.manualsdir.com/files/775184/content/doc035.png)
Closing Seam Machine 1282-4 Working Instructions
- 6 -
Beisler Automated Sewing Equipment
C.3
Start-up
C.3.2 Compressed air connection
The compressed air connection is preinstalled on the
machine. It comprises the following components:
•
Fig. 3: Pressure reducer
2
with manometer
4
and water separator
5
,
•
Quick-disconnect coupling
1
for pressure hose.
The pressure reducer is mounted to the left rear leg of the
worktable.
Connecting the machine to the compressed air sup-
ply system:
1. Connect pressure hose plug to on-site terminal unit.
2. Open on-site compressed air supply.
3. Set pressure reducer to a machine operating pressure
of 6 bar by rotating pressure reducer knob
3
and read
value on manometer
4
:
• To increase pressure, rotate in clockwise direction,
• To reduce pressure, rotate in counter-clockwise
direction.
C.3.3 Sewing unit
Prior to connecting the machine to the power supply sy-
stem and performing a test run, the condition of the se-
wing unit must be checked.
•
Fig. 4: Retighten retaining screws
1
and
2
of the
sewing unit stitch plate.
Fig. 3 / 4
Fig. 3