Set motor parameters:
Mark the symbol „Motor parameters“ .
Press the
key until the following will be displayed:
Pull: 75
5400
[ 4500]
MAX.: 8000
MIN.: 400
DEC.
80%
ACC.
100%
RESET
ON
SETUP-02
67
Use the
keys to mark the different values in
the window.
Use the
keys to adjust the desired values:
RESET
must be set to ‘ON’.
MIN.:
minimum revs of the sewing head; 400 is the optimized
value.
MAX.:
maximum revs of the sewing head:
Pegasus S52:
8000
PUL.:
mounted belt drive disc size; must be set to ‘75’
ACC.:
acceleration curve; must be set to ‘100%’
DEC.:
decrease parameter: must be set to 80%
KP:
add. motor break; must be set to 16